background image

Configuring Communication

78

7" Modero Touch Panels



Wired Ethernet - System Settings > IP Settings section within the IP Address field.



Wireless - Wireless Settings > IP Settings section within the IP Address field.



If you do not get this field continue to step 9.

9.

If a WebControl password was setup on the G4 WebControl page, a G4 Authentication Session
password dialog box appears on the screen within the secondary browser window.

10.

Enter the Web Control session password into the Session Password field (FIG. 75). This password
was previously entered into the Web Control Password field within the G4 Web Control page on the
panel.

11.

Click OK to send the password to the panel and begin the session. A confirmation message appears
stating "Please wait, Initial screen loading..".

The secondary window then becomes populated with the same G4 page being displayed on the target G4
panel. A small circle appears within the on-screen G4 panel page and corresponds to the location of the
mouse cursor. A left-mouse click on the computer-displayed panel page equates to an actual touch on the
target G4 panel page.

FIG. 76

Connection Details dialog

IP Address of touch panel
- obtained from IP Settings section of
the System/Wireless Settings page