Setting alarm activation level, Installing the translation file – Avaya S8710 User Manual

Page 48

Advertising
background image

3 Translating the IPSIs

Administering the IPSIs

48

Installing and Configuring the Avaya S8700 or S8710 Media Server

June 2004

Setting alarm activation level

1

Type

change system-parameters maintenance

and press Enter.

2

In the

CPE Alarm Activation Level

field, select

none

(default),

warning

,

minor

, or

major

,

depending on the level the customer wants and press

Enter

to effect the changes.

3

Repeat for each IPSI.

Installing the translation file

1

Type

save translations

and press Enter to save the translations to the hard drive.

change system-parameters maintenance

Page 1 of 3

MAINTENANCE-RELATED SYSTEM PARAMETERS

OPERATIONS SUPPORT PARAMETERS
CPE Alarm Activation Level: none

SCHEDULED MAINTENANCE
Start Time: 22 : 00
Stop Time: 06 : 00
Save Translation: daily
Update LSPs When Saving Translations: y
Command Time-out (hours): 2
Control Channel Interchange: no
System Clocks/IPSI Interchange: no