IM 01E20C01-01E

6-32

6. PARAMETER DESCRIPTION

[J23: Pulsing Flow]

Selection of pulsing flow support

In a situation where pulsating flow causes error in the
average flow value, due to the application of a plunger
pump, this parameter provides functionality whereby
calculation is controlled and variations in flow rate are
followed.

Setting

Function

Normal

Support for pulsing flow

No

Yes

T0639.EPS

[J24: T/P Damp Select]

Setting of damping opera-

tion
This parameter is used to select that the flow rate value
obtained through damping calculation for totalization
and pulse output or the instantaneous flow rate value
(no damping) for totalization and pulse output.

Setting

Function

Damping

No damping

Damp

No Damp

T0640.EPS

[J30: Power Synch]

Setting of power synchroniza-

tion
This parameter sellects whether or not the internal
frequency is to be synchronized with that of the power
supply.

Setting

Function

Not synchronized

Synchronized

No

Yes

T0641.EPS

[J31: Power Frequency]

Setting of power fre-

quency
When “Yes” (i.e., in synchrony) has been selected for

J30: Power Synch

, this parameter is used to display

the power supply frequency. If “No” (i.e., not synchro-
nized) has been selected, the power supply frequency is
to be specified.

IMPORTANT

In situations where a DC power supply is used
for converters, set the local commercial power
frequency in area where the converter is in-
stalled (size 2.5mm to 1000mm). Set “No” for
J30: Power Synch and the local commercial
power frequency for J31: Power Frequency.

IMPORTANT

In situations where AXFA11 is combined with a
remote flowtube the size of 1100 mm (44 in.) to

2600 mm (104 in.), set the fixed frequency
(49.00 Hz) in case that either AC or DC power
supplies is used for converters.
Set “No” for J30: Power Synch and “49.00” for
J31: Power Frequency.

Following settings are necessary by power supply and
by flow tube size.

Power Supply Code 1

(100 to 240 V AC or 100 to 120 V DC)

T0642-1.EPS

J30
J31

J30
J31

Size 2.5 mm (0.1 in.)
to 1000 mm (40 in.)

Power synchronous (Yes)
No setting

Power asynchronous (No)
49.00 Hz

Power asynchronous (No)

Power asynchronous (No)

Local commercial power
frequency

49.00 Hz

AC power
supply

DC power
supply

Size 1100 mm (44 in.)
to 2600 mm (104 in.)

Power Supply Code 2 (24 V AC/DC)

T0642-2.EPS

J30
J31

J30
J31

Size 2.5 mm (0.1 in.)
to 1000 mm (40 in.)

Power asynchronous (No)
Local commercial power
frequency

Power asynchronous (No)
49.00 Hz

Power asynchronous (No)

Power asynchronous (No)

Local commercial power
frequency

49.00 Hz

AC power
supply

DC power
supply

Size 1100 mm (44 in.)
to 2600 mm (104 in.)

[J40: Memo 1]

Setting of memo 1

[J41: Memo 2]

Setting of memo 2

[J42: Memo 3]

Setting of memo 3

These parameters are used with the memo function,
and up to 16 characters can be set for each.

[J50: Software Rev No]

Display of software

revision
This parameter is used to display the software’s
revision number.

(9) Menu K: Diagnostic Function Setting items

Menu K contains items that are relevant to the diagno-
sis of insulation adhesion to the electrode.

[K10: Adhesion Check]

Setting of adhesion

diagnostic function
This parameter selects whether or not the adhesion
diagnostic function will be carried out.