Panasonic CS-XE9PKUA User Manual

Page 28

Advertising
background image

28

11.2.3 Connect the Cable to the Indoor Unit

1 The inside and outside connection cable can

be connected without removing the front grille.

2 Unscrew the conduit cover and fix the conduit

connector to conduit cover with lock nut, then
secure it against chassis.

3 Connection cable between indoor unit and

outdoor unit should be UL listed or CSA
approved 4 conductor wires minimum AWG16
in accordance with local electric codes.

o

Ensure the colour of wires of outdoor unit
and terminal number are the same as the
indoor's respectively.

o

Earth lead wire shall be Yellow/Green
(Y/G) in colour and shall be longer than
other lead wires as shown in the figure
for electrical safety in case of slipping.

11.2.3.1 Wire Stripping and Connecting Requirement