Performance Test Condition

ARI

Power Supply

Phase, Hz

Single, 60

V 208

230

Min. Mid. Max. Min. Mid. Max.

Cooling

Capacity

kW

0.83 3.36 4.10 0.83 3.36 4.10

BTU/h

2800 11500 14000 2800 11500 14000

kcal/h – – – – – –

Running

Current

A

– 4.20 – – 3.80 –

Input

Power

W

150 800 1.05k 150 800 1.05k

Annual

Consumption kWh – – – – – –

EER

W/W

5.53 4.20 3.90 5.53 4.20 3.90

BTU/hW 18.65 14.35 13.30 18.65 14.35 13.30

kcal/hW – – – – – –

Power

Factor

%

– 92 – – 92 –

Indoor Noise (H / L / QLo)

dB-A

45 / 28 / 20

45 / 28 / 20

Power Level dB

61 / – / –

61 / – / –

Outdoor Noise (H / L / QLo)

dB-A

49 / – / –

49 / – / –

Power Level dB

64 / – / –

64 / – / –

Heating

Capacity

kW

0.89 4.05 6.72 0.89 4.05 6.72

BTU/h

3000 13800 23000 3000 13800 23000

kcal/h – – – – – –

Running

Current

A

– 5.80 – – 5.20 –

Input

Power

W

150 1.15k 2.10k 150 1.15k 2.10k

COP

W/W

5.93 3.52 3.20 5.93 3.52 3.20

BTU/hW 20.00 12.00 10.95 20.00 12.00 10.95

kcal/hW – – – – – –

Power

Factor

%

– 95 – – 96 –

Indoor Noise (H / L / QLo)

dB-A

44 / 35 / 32

44 / 35 / 32

Power Level dB

60 / – / –

60 / – / –

Outdoor Noise (H / L / QLo)

dB-A

49 / – / –

49 / – / –

Power Level dB

64 / – / –

64 / – / –

17°F: Rated Capacity (BTU/h) / I. Power (W)

10400 / 1.05k

5°F: Max. Capacity (BTU/h)

12500

Max Current (A) / Max Input Power (W)

9.5 / 2.15k

Starting Current (A)

5.80

Compressor

Type

Hermetic

Motor

(Rotary)

Motor Type

Brushless (4 poles)

Output Power

W

700