12.7 Powerful Mode Operation

š When the powerful mode is selected, the internal setting temperature will shift lower up to 3.6°F (2°C) (for

Cooling/Soft Dry) or higher up to 6.3°F (3.5°C) (for Heating) than remote control setting temperature for
20 minutes to achieve the setting temperature quickly.

12.8 Timer Control

š There are 2 sets of ON and OFF timer available to turn the unit ON or OFF at different preset time.

š If more than one timer had been set, the upcoming timer will be displayed and will activate in sequence.

12.8.1 ON

Timer

Control

š ON timer 1 and ON timer 2 can be set using remote control, the unit with timer set will start operate earlier than

the setting time.
This is to provide a comfortable environment when reaching the set ON time.

š 60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to

determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting
time.

š From the above judgment, the decided operation will start operate earlier than the set time as shown below.

12.8.2 OFF Timer Control

OFF timer 1 and OFF timer 2 can be set using remote control, the unit with timer set will stop operate at set time.

12.9 Auto Restart Control

š When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within

three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly) after power supply resumes.

š This type of control is not applicable during ON/OFF Timer setting.

š This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.

12.10 Indication Panel

LED POWER TIMER

POWERFUL/QUIET

RFP

ECONAVI

AUTO

COMFORT

Color Green Orange

Orange Green Green

Green

Light ON

Operation ON Timer Setting ON

POWERFUL/QUIET

Mode ON

RFP ON

ECONAVI ON

AUTO COMFORT

ON

Light OFF

Operation OFF Timer Setting OFF

POWERFUL/QUIET

Mode OFF

RFP OFF ECONAVI OFF

AUTO COMFORT

OFF


Note:

š If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation

mode judgment, or ON timer sampling.

š If Timer LED is blinking, there is an abnormality operation occurs.