15.4.20 F90 (Power Factor Correction Protection)

Malfunction Decision Conditions

š To maintain DC voltage level supply to power transistor.

š To detect high DC voltage level after rectification.


Malfunction Caused

š During startup and operation of cooling and heating, when Power Factor Correction (PFC) protection circuitry at

the outdoor unit main PCB senses abnormal DC voltage level for power transistors.

š When DC voltage detected is LOW, transistor switching will turn ON by controller to push-up the DC level.

š When DC voltage detected is HIGH (391Vdc – 425Vdc), active LOW signal will send by the controller to turn OFF

relay RY-C.


Troubleshooting