Diagnosis

display

Abnormality /

Protection control

Abnormality

Judgment

Protection

Operation

Problem Check

location

H98

Indoor high pressure
protection

— —

Indoor high pressure
protection (Heating)

š Check indoor heat exchanger

š Air filter dirty

š Air circulation short circuit

H99

Indoor operating unit
freeze protection

— —

Indoor freeze protection
(Cooling)

š Check indoor heat exchanger

š Air filter dirty

š Air circulation short circuit

F11

4-way valve
switching
abnormality

4 times happen
within 30 minutes

4-way valve switching
abnormal

š 4-way valve

š Lead wire and connector

F17

Indoor standby units
freezing abnormality

3 times happen
within 40 minutes

Wrong wiring and
connecting pipe, expansion
valve leakage, indoor heat
exchanger sensor open
circuit

š Check indoor/outdoor

connection wire and pipe

š Indoor heat exchanger sensor

lead wire and connector

š Expansion valve lead wire and

connector

F90

Power factor
correction
(PFC) circuit
protection

4 times happen
within 10 minutes

Power factor correction
circuit abnormal

š Outdoor PCB faulty

F91

Refrigeration cycle
abnormality

2 times happen
within 20 minutes

Refrigeration cycle
abnormal

š Insufficient refrigerant or valve

close

F93

Compressor
abnormal revolution

4 times happen
within 20 minutes

Compressor abnormal
revolution

š Power transistor module faulty

or compressor lock

F94

Compressor
discharge overshoot
protection

4 times happen
within 30 minutes

Compressor discharge
pressure overshoot

š Check refrigeration system

F95

Outdoor cooling high
pressure protection

4 times happen
within 20 minutes

Cooling high pressure
protection

š Check refrigeration system

š Outdoor air circuit

F96

Power transistor
module overheating
protection

4 times happen
within 30 minutes

Power transistor module
overheat

š PCB faulty

š Outdoor air circuit (fan motor)

F97

Compressor
overheating
protection

3 times happen
within 30 minutes

— Compressor

overheat

š Insufficient refrigerant

F98

Total running current
protection

3 times happen
within 20 minutes

— Total

current

protection

š Check refrigeration system

š Power source or compressor

lock

F99

Outdoor direct
current (DC) peak
detection

Continuous
happen for 7 times

Power transistor module
current protection

š Power transistor module faulty

or compressor lock