SPECIFICATIONS

Magic-Pak: HW/HWC

2-4

SRM-HW/HWC 2/99

FIGURE 2-1

Connection Diagram

GREEN

BLA

C

K

BLK

M

ORN

ORN

VIOLET

RED

BLUE

WHT

RED

BLACK

BLUE

YELLOW

WH

IT

E

GREEN

RED

FLAME ROD

ELECTRODE

4

6

2

R

G

W

C

Y

BLA

C

K

BLA

C

K

BLA

C

K

GAS

VALVE

MANUAL RESET

LIMIT SWITCH

COMBUSTION

BLOWER

RED

BLUE

YELLO

W

RED

YELLOW

D

208 V

RED

BLUE

240 V

CAPACITOR

CAPACITOR

BLOWER

208/230-1-60

POWER SUPPLY

COPPER CONDUCTORS

ONLY

}

THERMOSTAT

}

JUMPER REQUIRED

*

*

*

*

HIGH(BLACK)

HIGH(BLACK)

HIGH(BLACK)

64HWC303

64HWC303

HIGH(BLACK)

MED (BLUE)

51HWC303

51HWC303

MED (BLUE)

MED (BLUE)

HIGH(BLACK)

HIGH(BLACK)

64HWC243

64HWC243

MED (BLUE)

MED (BLUE)

MED (BLUE)

51HWC243

51HWC243

MED (BLUE)

MED (BLUE)

LOW (RED)

38HWC243

38HWC243

LOW (RED)

LOW (RED)

HIGH(BLACK)

HIGH(BLACK)

64HWC183

64HWC183

LOW (RED)

LOW (RED)

MED (BLUE)

51HWC183

51HWC183

LOW (RED)

LOW (RED)

LOW (RED)

38HWC183

MED (BLUE)

MED (BLUE)

HIGH(BLACK)

HIGH(BLACK)

38HWC123

38HWC123

MED (BLUE)

MED (BLUE)

LOW (RED)

26HWC123

26HWC123

T2

T1

L2

L1

COOLING

COOLING

HEATING

HEATING

MODELS

MODELS

EVAP. MOTOR SPEED CONNECTIONS

EVAP. MOTOR SPEED CONNECTIONS

BLA

C

K

BLA

C

K

RED

BLACK

BLACK

RED

RED

YELLOW

YELLOW

BLUE

BLACK

VIOLET

YELLOW

RED

BLUE

BLUE

BLACK

BROWN

BROWN

NOTE:

IF ANY OF THE ORIGINAL

WIRES ARE REPLACED, THE
SAME SIZE AND TYPE WIRE
MUST BE USED.

W

Y

G

R

LINE VOLTAGE-FACTORY
LINE VOLTAGE-FACTORY WHEN USED

LINE VOLTAGE-FIELD
LOW VOLTAGE-FACTORY

LOW VOLTAGE-FIELD

W

Y

G

R

GND

24V

A

C

UNUSED

HEA

T

COOL

L1

CMB

L

H

R

C

S

FAN

COM

HERM

SEE CHART

CHART

FOR WIRING

PRESSURE

SW

IT

CH

AUTO RESET

LIMIT SWITCH

IGNITION

CONTROL

CONTROL

TRANSFORMER

TRANSFORMER

CONTACTOR

BLOWER

CONTROL

BLOWER

CONTROL

BLOWER

MOTOR

CAPACITOR-RUN

CONDENSER FAN

CONDENSER FAN

COMP

CONNECTOR

CONNECTOR BLOCK

BLOCK

ORN

VIOLET

BLK

CONNECTION DIAGRAM

CONNECTION DIAGRAM

CIRCUITS ENERGIZED

OPERATING MODE CIRCUIT

HEATING

R-W

COOLING

R-G-Y

FAN

R-G

3

1

5

1

2

3

4

5

#45004-1

DIAGNOSTICS

The following blower/ignition control board
LED codes will indicate normal or abnormal
operations:

SLOW FLASH

Normal Operation, No
Call for Heat

FAST FLASH

Normal Operation, Call for
Heat

2 FLASH

System Lockout - Failed to
Detect or Sustain Flame

3 FLASH

Pressure Switch Open or
Closed

4 FLASH

High Limit or Rollout
Switch Open

5 FLASH

Flame Sensed and Gas
Valve Not Energized

STEADY

Internal Failure
(Micro-controller Failure;
Self-check)

HWC123, 183, 243, 303

(w/United Technologies 1097 Spark Ignition System)

Note: On units that are equipped with a low ambient switch (designated

with an “SA” in the model number), sequence of operation during
cooling call is modified when

outdoor

temperatures fall below the

normal operating range. For more information on the low ambient
switch equipped version of this unit, see the section beginning on
page 2-36.