5-16

UNIT COMPONENTS

Magic-Pak: HW/HWC

SRM-HW/HWC 2/99

Flame Carryover Problems

During ignition, the flame must travel uninterrupted from one burner to the
rest of the burners.

Causes:

Carryover “wing” on burner is plugged with insects or debris

Improper gap setting on wings

Incorrect gas pressure

The burner wing has a specified gap (typically 0.025" +/– .002"), which
must carry gas and a small flame to allow flame carryover from one
burner to the next. Check the gap settings on all burners.

Orifice

Smooth end slips
into burner

Gas Entry

Threads
into manifold

Flame Exit

.025 gap (+/ .002 )

for flame carryover

"

–

"

FIGURE 5-11

Inshot Burners

FIGURE 5-12 Burner Wing Gap

Armstrong P/N: 41948-001

Gap = .025" +/– .002"