Hw (heating only), W/fenwal triton 2461d dsi ignition control), Specifications magic-pak: hw/hwc – Armstrong World Industries HWC PREMIER 183 User Manual

Page 32: Figure 2-4 connection diagram, Circuits energized

Advertising
background image

SPECIFICATIONS

Magic-Pak: HW/HWC

2-22

SRM-HW/HWC 2/99

#39247D2

HW (Heating Only)

(w/Fenwal Triton 2461D DSI Ignition Control)

CIRCUITS ENERGIZED

OPERATING MODE

CIRCUIT

HEATING

R-W

LINE VOLTAGE - FACTORY
LINE VOLTAGE - FACTORY (WHEN USED)
LINE VOLTAGE - FIELD
LOW VOLTAGE - FACTORY

LOW VOLTAGE - FIELD

LOW VOLTAGE - FACTORY (WHEN USED)

208/230-1-60

POWER SUPPLY

COPPER CONDUCTORS

ONLY

THERMOSTAT

Y

NOTE:

IF ANY OF THE ORIGINAL
WIRES ARE REPLACED,
THE SAME SIZE AND TYPE
WIRE MUST BE USED.

MOTOR SPEED CONNECTIONS

MODELS

26HW
38HW
51HW
64HW

HEATING

LOW (RED)

HIGH (BLACK)

MED (BLUE)

HIGH (BLACK)

PINK

BROWN

WHITE

ORANGE

BLUE

ORANGE

BLUE

BLACK

BLACK

BLACK
BLACK

BLACK

YELLOW

YELLOW

BROWN

BLUE

BLACK

RED

RED

WHITE

SEE CHART

FOR WIRING

BLA

C

K

BLA

C

K

WH

IT

E

WH

IT

E

RED

GREEN

RED

RED

WH

IT

E

WH

IT

E

GREEN

BLUE

YELLO

W

RED

WH

IT

E

GREEN

BLUE

BLUE

TH

P.SW

L1

IND

V1

24VAC

V2

GND

ELECTRODE

CABLE

IGNITION

CONTROL

GAS

VALVE

COMBUSTION

BLOWER

MANUAL

RESET

LIMIT

SWITCH

PRESSURE

SWITCH

CAPACITOR

BLOWER

BLOWER

MOTOR

BLOWER

BLOWER

CONTROL

208

240

TRANS-

FORMER

C

NO

NC

R

W

Y

G

R

W

G

R

W

C

L1

H

FIGURE 2-4

Connection Diagram

Advertising