Unit components magic-pak: hw/hwc, Flame rollout switch (*55) – Armstrong World Industries HWC PREMIER 183 User Manual

Page 83

Advertising
background image

5-20

UNIT COMPONENTS

Magic-Pak: HW/HWC

SRM-HW/HWC 2/99

Flame Rollout Switch (*55)

A Normally Closed switch that opens when abnormal temperatures occur
in the burner area, caused by a restricted heat exchanger, causing main
burner flame to “roll out” into the vestibule area.

To reset the switch, push the button on top. The button is a different color
from the body.

Reset Button

FIGURE 5-17

Flame Rollout Switch

Cutout Temperature:
Marked on body of switch
Nominal Switch Contact Rating:
15 A @ 120VAC