Armstrong World Industries HWC PREMIER 183 User Manual

Page 58

Advertising
background image

4-3

Service Reference Manual

COMPONENT LOCATION ILLUSTRATIONS

SRM-HW/HWC 2/99

HW/HWC122, 182, 242, 302

FENWAL IGNITION CONTROL - 2 MODELS (*24)

FENWAL TRITON 2461D 900-227 - ARMSTRONG P/N 43110-002

FENWAL 05-29 - ARMSTRONG P/N 39048B001

(SEE NOTE BELOW)

FLUE BOX

MAIN LIMIT
SWITCH (*52)

INDUCED DRAFT BLOWER/
COMBUSTION BLOWER (*63)
ARMSTRONG P/N 41144-001

GAS VALVE (*7)
WHITE RODGERS 25K49-120
ARMSTRONG P/N 43108-001

COMBUSTION AIR INLET (5")

BURNER COVER

BURNER TRAY ASSEMBLY
BECKETT BURNER MODELS:
TL109A-26K
TL109B-38K
TL109C-51K
TL109D-64K

FLAME ROLLOUT SWITCH (*55)

PRESSURE SWITCH (*57)

INDIVIDUAL BURNERS (*34)
BECKETT - ARMSTRONG P/N 41948-001
ARMSTRONG - ARMSTRONG P/N 39006B001

HEATING SECTION

CONTROL SECTION

COOLING SECTION

SEE COMPONENT SECTION FOR FURTHER

DETAIL OF IGNITION/BLOWER CONTROL MODELS

NOTE:

FIGURE 4-2

The numbers in parentheses in the drawing above refer to the section number each part is assigned. These num-
bers are provided here to aid in locating the parts in the Parts List section found beginning on page 8-1.