Ip55 quick start up guide – Beijer Electronics BFI-H2 V1.12 User Manual

Page 2

Advertising
background image

User Guide Revision 1.12


2

IP55 Quick Start Up Guide

















Supply Voltage
























Keypad Operation can be found in
section 5.5

Run / Stop 10K Pot

HVAC Display
(Status, Diagnostics, and Programming)

Motor Cable
For correct cable size, see Technical
Data i
n section 13.4.
Observe the maximum permissible
motor cable length.
For Motor cable lengths > 50 metres, an
output filter is recommended.
Use a screened (shielded cable). The
shield should be bonded to earth at
both ends.

Motor Connection

Check for Star or Delta connection
according to the motor voltage rating in
section 4.5.

Motor Nameplate Details

Motor Rated Voltage: P1-07
Motor Rated Current: P1-08
Motor Rated Frequency: P1-09
Motor Rated Speed (Optional): P1-10

Fuses or MCB
Check Drive
Rating info in
section 13.4

AC Supply Connection
200 – 240 Volts + / - 10%
380 – 380 Volts + / - 10%
Check Drive Input Voltage
information in section 13.2

PE L1 L2 L3

Control Terminal
Configuration based on factory settings

Mechanical Mounting

Information can be found in section 3.6.

Hardware Enable
Link the terminals as shown, optionally
through switch contacts to enable drive
operation

Close the switch to run (enable)
Open the switch to stop

RJ45
Connector