Beijer Electronics BFI-H2 V1.12 User Manual

Page 66

Advertising
background image

User Guide Revision 1.12


66

200 - 240 Volt (+ / - 10%) 3 Phase Input, 3 Phase Output

kW

HP

Nominal

Input

Current

Fuse

Or

MCB (Type B)

Supply

Cable

Size

Nominal

Output

Current

Motor

Cable

Size

Maximum

Motor

Cable Length

A

Non UL

UL (A)

mm

AWG / kcmil

A

mm

AWG / kcmil

m

0.75

1

5.7

10

10

1.5

14

4.3

1.5

16

100

1.5

2

8.4

10

10

2.5

14

7

1.5

16

100

2.2

3

13.1

16

15

4

12

10.5

1.5

16

100

4

5

17.3

20

20

4

10

18

2.5

16

100

5.5

7.5

25

32

30

10

8

24

4

14

100

7.5

10

32.9

40

35

16

8

30

6

12

100

11

15

54.1

63

60

25

4

46

10

8

100

15

20

69.6

80

80

35

3

61

16

6

100

18.5

25

76.9

100

100

35

1

72

25

6

100

22

30

92.3

125

125

50

2/0

90

35

4

100

30

40

116.9

160

150

70

3/0

110

50

2

100

37

50

150.2

200

175

95

4/0

150

70

1

100

45

60

176.5

200

200

120

250

180

95

2/0

100

55

75

211

250

225

185

300

202

120

3/0

100

75

120

267

315

300

2 x 95

500

248

150

4/0

100

380 - 480 Volt (+ / - 10%) 3 Phase Input, 3 Phase Output

kW

(400V)

HP

(460V)

Nominal

Input

Current

Fuse

Or

MCB (Type B)

Supply

Cable

Size

Nominal

Output

Current

Motor

Cable

Size

Maximum

Motor

Cable Length

A

Non UL

UL (A)

mm

AWG / kcmil

A

mm

AWG / kcmil

m

0.75

1

3.1

6

6

1.5

14

2.2

1.5

16

100

1.5

2

4.8

6

6

1.5

14

4.1

1.5

16

100

2.2

3

7.2

10

10

1.5

14

5.8

1.5

16

100

4

5

10.8

16

15

2.5

12

9.5

1.5

16

100

5.5

7.5

13.3

16

15

4

12

14

1.5

16

100

7.5

10

18.5

25

25

4

8

18

2.5

16

100

11

15

26.5

32

30

10

8

24

4

14

100

15

20

32.9

40

40

16

8

30

6

12

100

18.5

25

46.6

63

60

16

4

39

10

10

100

22

30

54.1

63

60

25

4

46

10

8

100

30

40

69.6

80

80

35

3

61

16

6

100

37

50

76.9

100

100

35

1

70

25

6

100

45

60

92.3

125

125

50

2/0

90

35

4

100

55

75

116.9

160

150

70

3/0

110

50

2

100

75

100

150.2

200

175

95

4/0

150

70

1

100

90

150

176.5

200

200

120

250

180

95

2/0

100

110

175

217.2

250

250

185

400

202

120

3/0

100

132

200

255.7

315

300

2 x 95

500

240

150

4/0

100

160

250

302.4

400

350

2 x 95

700

302

2 x 70

350

100

200

300

370

400

400

2 x 150

900

370

2 x 95

500

100

250

350

450

500

500

2 x 150

1500

450

2 x 120

700

100

Note

The maximum motor cable length stated applies to using a screened motor cable. When using an unscreened cable, the maximum cable
length limit is increased by 50%. When using the Invertek Drives recommended output choke, the maximum cable length limited can be
increased by 100%

The PWM output switching from any inverter when used with a long motor cable length can cause an increase in the voltage at the motor
terminals, depending on the motor cable length and inductance. The rise time and peak voltage can affect the service life of the motor.
Invertek Drives recommend using an output choke for motor cable lengths of 50m or more to ensure good motor service life

For UL compliant installation, use Copper wir4 with a minimum insulation temperature rating of 75°C. When using fuses type should be
Class CC or Class J

Advertising