Beijer Electronics BFI-H2 V1.12 User Manual

Page 25

Advertising
background image

User Guide Revision 1.12

25

5.3. Advanced Keypad Operation Short Cuts – Standard LED Keypad (IP20 Drives)

Function

When Display shows...

Press...

Result

Example

Fast Selection of

Parameter Groups

Note : Parameter Group
Access must be enabled

P1-14 = 101

xxx

+

The next highest

Parameter group is

selected

Display shows



Press

+

Display shows



xxx

+

The next lowest

Parameter group is

selected

Display shows



Press

+

Display shows



Select lowest Group

Parameter

xxx

+

The first parameter of a

group is selected

Display shows



Press

+

Display shows



Set Parameter to

minimum value

Any numerical value

(Whilst editing a

parameter value)

+

The parameter is set to

the minimum value

When editing P1-01

Display shows

.

Press

+

Display shows

.

Adjusting individual digits

within a parameter value

Any numerical value

(Whilst editing a

parameter value)

+

Individual parameter

digits can be adjusted

When editing P1-10

Display shows

Press

+

Display shows



Press

Display shows



Press

+

Display shows



Press

Display shows



Etc...

5.4. Drive Operating Displays – Standard LED Keypad (IP20 Drives)

Display

Status



Drive mains power applied, but no Enable or Run signal applied



Motor Autotune in progress.

x.x

Drive running, display shows output frequency (Hz)

Whilst the drive is running, the following displays can be

selected by briefly pressing the

button on the drive.

Each press of the button will cycle the display through to the
next selection.

x.x

Drive running, display shows motor current (Amps)

x.x

Drive Running, display shows motor power (kW)

x.x

Drive Running, display shows customer selected units, see
parameters P2-21 and P2-22



Drive mains power not present, external 24 Volt control power supply present only



Hardware enable circuit open. External links are required to the STO inputs (terminals 12 and 13) as shown in section 4.7
Connection Diagram



Parameters reset to factory default settings



Parameters reset to User default settings

For drive fault code displays, refer to section 15.1

5.5. Keypad Layout and Function – Standard OLED Keypad (IP55 and IP66 Drives)

OLED Display

Advertising