6.13

Scrambler Key Initialization Register - Address 14h

15

14

13

12

11

10

9

8

Load

Reserved

Scrambler Initialization Key

7

6

5

4

3

2

1

0

Scrambler Initialization Key

BIT

NAME

TYPE

RESET

DESCRIPTION

15

Load

Read/Set

0

When this bit is set, the scrambler will be loaded with
the value in the Scrambler Initialization Key field.
When the load is complete, this bit will clear automat-
ically.

14:11 Reserved

Read Only

0000

These bits should be read as don’t cares and, when
written, should be written to 0.

10:0

Scrambler Initializa-
tion Key

Read/Write Reset value is

dependent on the
PHY Address field
of the Self Status
Register (address
19h).

This field allows the Scrambler to be loaded with a
user-definable key sequence. A value of 000h has
the effect of bypassing the scrambler function.

This is valuable for testing purposes to allow a deter-
ministic response to test stimulus without a synchro-
nization delay.

Note: This field is disabled, and writes to this bit are
ignored when the National Compatibility Mode bit of
the 10BASE-T Configuration Register (address 1Ch)
is set.