The Advanced MCACC menu

11

113

En

By analyzing the graph, you should be able to see how
your room is responding to certain frequencies.
Differences in channel level and speaker distance are
taken into account automatically (compensation is
provided for comparison purposes), and the frequency
measurements can be examined both with and without
the equalization performed by this receiver.

1

Setting Acoustic Calibration EQ Professional
according to your room characteristics

Using the manual setup, you can set the time period at
which the frequency response is analyzed, pinpointing
the time that is best for system calibration with your
particular room characteristics.

The graph below shows the difference between
conventional acoustic calibration and professional
calibration (the gray circle indicates the point where the
microphone captures sound during frequency analysis).

As soon as audio is output from your speaker system, it
is influenced by room characteristics, such as walls,
furniture, and the dimensions of the room. The sooner
the frequency analysis, the less it is influenced by the
room. We recommend an earlier time setting of

30-50ms

to compensate for two major factors that will influence
the sound of most rooms:

Reverberance of high vs. low frequencies
Depending on your room, you may find that lower
frequencies seem overly reverberant compared to
higher frequencies (i.e. your room sounds ‘boomy’).
This may result in a skewed frequency analysis if the
measurement is done too late.

Reverb characteristics for different channels
Reverb characteristics can be somewhat different for
each channel. Since this difference increases as the
sound is influenced by the various room
characteristics, it is often better to capture a
frequency analysis early on for smoother mixing of
channel frequencies/sounds.

If your room isn’t affected by the factors above, it is often
not necessary to make a

30-50ms setting. Later time

settings may provide a more detailed sound experience
with your speaker system. It is best to try and see what
works best for your particular room.

Note that changing the room (for example, moving
furniture or paintings) will affect the calibration results.
In such cases, you should recalibrate your system.

Using Acoustic Calibration EQ Professional

1

Select ‘EQ Professional’, then press ENTER.

2

Select an option and press ENTER.

Reverb Measurement – Use this to measure the
reverb characteristics of your room (for graphical
output using a PC, see

Connecting a PC for Advanced

MCACC output on page 40 to connect an RS-232C
cable before selecting this option).

Reverb View – You can check the reverb
measurements made for specified frequency ranges
in each channel.

2

Note

1 Note that due to an effect known as ‘group delay’, lower frequencies will take longer to be generated than higher frequencies (this is most

obvious when comparing the frequencies at 0 ms). This initial slope is not a problem (i.e. excessive reverb) with your listening room.

Level

Test tone

Acoustic Cal. EQ Pro.
calibration range

Conventional MCACC
EQ calibration range

Time
(in msec)

80

160

0

Level

Low
frequencies

Acoustic Cal. EQ Pro.
calibration range

Time
(in msec)

80

160

High
frequencies

Conventional MCACC
EQ calibration range

0

2 If the

Reverb View procedure is performed after the Automatically setting up for surround sound (Auto MCACC & Full Band Phase Control) on

page 45 or

Reverb Measurement operation, depending on the standing wave control setting, differences may appear on the reverb graph.

With the Auto MCACC function, the reverberations are measured with the standing waves controlled, so the reverb characteristics graph
shows the characteristics with the effect of the standing waves eliminated. By contrast, the

Reverb Measurement function measures the

reverberations without controlling the standing waves, so the graph indicates the reverb characteristics including the effect of the standing
waves. If you wish to check the reverb characteristics of the room itself (with the standing waves as such), we recommend using the

Reverb

Measurement function.

Level

Front L

Acoustic Cal. EQ Pro.
calibration range

Time
(in msec)

80

160

Front R

Conventional MCACC
EQ calibration range

0

1. Fine Channel Level
2. Fine SP Distance
3. Standing Wave

1c.Manual MCACC

4. EQ Adjust

5. EQ Professional

A/V RECEIVER

Exit

Return

6. Precision Distance

Precision Distance is only for
SC-LX82.

a. Reverb Measurement

b. Reverb View
c. Advanced EQ Setup

1c5.EQ Professional

A/V RECEIVER

Exit

Return

SC-LX82_LX72.book Page 113 Thursday, April 23, 2009 7:05 PM