The Advanced MCACC menu

11

114

En

Advanced EQ Setup – Use this to select the time
period that will be used for frequency adjustment and
calibration, based on the reverb measurement of
your listening area. Note that customizing system
calibration using this setup will alter the settings you
made in

Automatically setting up for surround sound

(Auto MCACC & Full Band Phase Control) on page 45
or

Automatic MCACC (Expert) on page 107 and is not

necessary if you’re satisfied with these settings.

3

If you selected ‘Reverb Measurement’, select EQ

ON or OFF, and then START.

The following options determine how the reverb
characteristics of your listening area are displayed in
Reverb View and Output PC (see Connecting a PC for
Advanced MCACC output
on page 40):

EQ OFF – You will see the reverb characteristics of
your listening area

without the equalization

performed by this receiver (before calibration).

EQ ON – You will see the reverb characteristics of
your listening area

with the equalization performed

by this receiver (after calibration).

1

Note that the EQ

response may not appear entirely flat due to
adjustments necessary for your listening area.

2

When the reverb measurement is finished, you can select
Reverb View to see the results on-screen. See
Professional Calibration EQ graphical output on page 134
for troubleshooting information.

4

If you selected ‘Reverb View’, you can check the

reverb characteristics for each channel. Press RETURN
when you’re done.

The reverb characteristics are displayed when the

Full

Auto MCACC or Reverb Measurement measurements
are conducted.

3

Use

/ to select the channel, frequency and

calibration setting you want to check. Use

/ to go

back and forth between the three. The reverb
characteristics graph before and after EQ calibration can
be displayed by selecting

Calibration : Before / After.

4

Note that the markers on the vertical axis indicate
decibels in 2 dB steps.

5

If ‘Advanced EQ Setup’ is selected, select the

MCACC memory to be stored, then enter the desired
time setting for calibration, and then select START.
Based on the reverb measurement above, you can
choose the time period that will be used for the final
frequency adjustment and calibration. Even though you
can make this setting without reverb measurement, it is
best to use the measurement results as a reference for
your time setting. For an optimal system calibration
based on the direct sound coming from the speakers, we
recommend using the

30-50ms setting.

Use

/ to select the setting. Use / to switch

between them.

Select the setting from the following time periods (in
milliseconds):

0-20ms, 10-30ms, 20-40ms, 30-50ms, 40-

60ms, 50-70ms and 60-80ms. This setting will be applied
to all channels during calibration.

When you’re finished, select

START. It will take about 2

to 4 minutes for the calibration to finish.

After the Acoustic Calibration Equalization is set, you are
given the option to check the settings on-screen.

Precision Distance (SC-LX82 only)

Before using this function, perform the Full Auto MCACC
Setup procedure (see page 45). Performing the Full Auto
MCACC procedure corrects the distance to a precision of
1 cm, but the Precision Distance function lets you adjust
the distance to the speakers (their position) with a
precision of under 1 cm. Here, rather than correct the

Note

1 The calibration corresponding to the currently selected MCACC preset will be used when

EQ ON is selected. To use another MCACC preset,

exit the

HOME MENU and press MCACC to select it before pressing HOME MENU.

2 After auto calibration with

EQ Type : SYMMETRY (Full Auto MCACC, etc.), the graph for the inferred reverb characteristics can be displayed

by selecting

Reverb View. To display the actually measured reverb characteristics after EQ calibration, measure with EQ ON.

MCACC :

M1.MEMORY 1

1c5a.Reverb Measurement

A/V RECEIVER

Exit

Cancel

START

Reverb Measure with :

EQ OFF

1c5b.Reverb View

Exit

Return

Channel : Front

M1.MEMORY 1

Calibration :

After

Frequency :

63Hz

SYMMETRY

A/V RECEIVER

dB

53.0

55.0

57.0

59.0

61.0

63.0

16 kHz

8 kHz
4 kHz
2 kHz
1 kHz

500 Hz
250 Hz
125 Hz

63 Hz

0

40

80

120

160 ms

3 The

After display when measurements have been made using the Full Auto MCACC or Auto MCACC (ALL) function shows the graph for the

inferred reverb characteristics after

EQ Type : SYMMETRY calibration.

4 The reverb characteristics graph is overwritten each time the reverberations are measured.

No Data is displayed if there is no reverb

characteristic data, for example before measurements have been taken.

MCACC :

M1.MEMORY 1

1c5c.Adv.EQ Setup

A/V RECEIVER

Exit

Cancel

START

Time Position

:

30-50ms

EQ Type

:

SYMMETRY

STAND.WAVE Multi-P :

NO

MCACC :

M1.MEMORY 1

1c5c.Adv.EQ Setup

A/V RECEIVER

Exit

Cancel

START

Time Position

:

30-50ms

EQ Type

:

SYMMETRY

STAND.WAVE Multi-P :

NO