Upflow ownflow horizontal – Bryant 2-stage Deluxe Induced-Combustion 4-way Multipurpose 120 User Manual

Page 13

Advertising
background image

13

Table 4 – Opening dimensions (In.)

FURNACE

CASING

WIDTH

APPLICATION

PLENUM OPENING

FLOOR OPENING

A

B

C

D

14–3/16

Upflow Applications on Combustible or Noncombustible

Flooring (KGASB subbase not required)

12---11/16

21---5/8

13---5/16

22---1/4

Downflow Applications on Noncombustible Flooring (KGASB

subbase not required)

12---9/16

19

13---3/16

19---5/8

Downflow applications on combustible flooring

(KGASB subbase required)

11---13/16

19

13---7/16

20---5/8

Downflow Applications on Combustible Flooring with CD5 or

CK5 Coil Assembly or KCAKC coil box

(KGASB subbase not required)

12---5/16

19

13---5/16

20

17–1/2

Upflow Applications on Combustible or Noncombustible

Flooring (KGASB subbase not required)

16

21---5/8

16---5/8

22---1/4

Downflow Applications on Noncombustible Flooring

(KGASB subbase not required)

15---7/8

19

16---1/2

19---5/8

Downflow applications on combustible flooring

(KGASB subbase required)

15---1/8

19

16---3/4

20---5/8

Downflow Applications on Combustible Flooring with CD5 or

CK5 Coil Assembly or KCAKC coil box

(KGASB subbase not required)

15---1/2

19

16---1/2

20

21

Upflow Applications on Combustible or Noncombustible

Flooring (KGASB subbase not required)

19---1/2

21---5/8

20---1/8

22---1/4

Downflow Applications on Noncombustible Flooring

(KGASB subbase not required)

19---3/8

19

20

19---5/8

Downflow applications on combustible flooring

(KGASB subbase required)

18---5/8

19

20---1/4

20---5/8

Downflow Applications on Combustible Flooring with CD5 or

CK5 Coil Assembly or KCAKC coil box

(KGASB subbase not required)

19

19

20

20

24---1/2

Upflow Applications on Combustible or Noncombustible

Flooring (KGASB subbase not required)

23

21---1/8

23---5/8

22---1/4

Downflow Applications on Noncombustible Flooring

(KGASB subbase not required)

22---7/8

19

23---1/2

19---5/8

Downflow applications on Combustible flooring

(KGASB subbase required)

22---1/8

19

23---3/4

20---5/8

Downflow Applications on Combustible Flooring with CD5 or

CK5 Coil Assembly or KCAKC coil box

(KGASB subbase not required)

22---1/2

19

23---1/2

20

UPFLOW

OWNFLOW

HORIZONTAL

YES

NOT
RECOMMENDED

YES

YES

YES

120û

MIN

YES

120û

MIN

YES

120û

MIN

90ы

90ы

NOT
RECOMMENDED

NOT
RECOMMENDED

D

A02329

Fig. 14 -- Duct Flanges