Warning – Bryant 2-stage Deluxe Induced-Combustion 4-way Multipurpose 120 User Manual

Page 18

Advertising
background image

18

Table 5 -- Air Delivery -- CFM (With Filter)* (Cont.)

FURNACE

SIZE

RETURN---AIR

INLET

SPEED

EXTERNAL STATIC PRESSURE (IN. WC)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

135---16 /

048135

Bottom

or

Side(s)

High

Med---High

Med---Low

Low

2090

1790

1545

1325

2010

1755

1525

1320

1930

1705

1500

1295

1835

1640

1450

1265

1710

1550

1380

1210

1590

1465

1315

1150

1470

1360

1215

995

1335

1210

1005

865

1025

945

855

745

835

785

670

540

135---22 /

066135

Bottom

Only

High

Med---High

Med---Low

Low

2485

2195

1880

1640

2400

2150

1850

1635

2310

2090

1820

1615

2215

2000

1780

1585

2110

1920

1715

1530

2000

1825

1635

1465

1880

1720

1540

1370

1725

1565

1415

1255

1535

1405

1290

1150

1355

1255

1160

1040

Bottom Sides

or

1 Side & Bottom

High

Med---High

Med---Low

Low

--- ---

2180

1880

1640

--- ---

2145

1850

1635

2385

2060

1820

1615

2305

2010

1780

1585

2195

1945

1715

1530

2085

1865

1635

1465

1960

1765

1540

1370

1825

1660

1415

1255

1670

1515

1290

1150

1465

1325

1160

1040

1 Side Only

High

Med---High

Med---Low

Low

2320

2125

1845

1640

2250

2065

1825

1620

2155

1995

1765

1580

2055

1910

1710

1540

1970

1815

1650

1485

1855

1710

1570

1410

1725

1610

1475

1330

1600

1490

1370

1220

1450

1340

1240

1080

1280

1175

1100

960

155---20 /

060155

Bottom Only

High

Med---High

Med---Low

Low

2465

2115

1800

1570

2430

2105

1790

1565

2375

2075

1770

1550

2305

2030

1735

1525

2230

1980

1695

1495

2110

1910

1640

1445

2000

1830

1570

1370

1865

1725

1465

1270

1725

1590

1345

1175

1545

1425

1225

1070

Both Sides Or 1

Side & Bottom

High

Med---High

--- ---

2155

--- ---

2135

2375

2095

2285

2040

2200

1975

2105

1895

1995

1790

1870

1685

1730

1550

1570

1400

1 Side Only

High

Med---High

--- ---

2140

--- ---

2095

2260

2040

2180

1975

2085

1890

1975

1810

1865

1705

1740

1595

1605

1480

1455

1325

*A filter is required for each return---air inlet. Airflow performance included 1---in. washable filter media such as contained in factory---authorized accessory filter

rack. To determine airflow performance without this filter, assume an additional 0.1 in. wc available external static pressure.

--- --- Indicates unstable operating conditions.

NOTE: For horizontal applications, the top--most flange may be
bent past 90_ to allow the evaporator coil to hang on the flange
temporarily while the remaining attachment and sealing of the
coil are performed.
Downflow Furnaces
Connect supply--air duct to supply--air outlet on furnace. Bend

flange inward past 90_ with wide duct pliers. (See Fig. 14.) The

supply--air duct must be connected to ONLY the furnace
supplyoutlet or air conditioning coil casing (when used). When

installed on combustible material, supply--air duct must be
connected to ONLY the accessory subbase, KGASB0201ALL, or

a factory approved air conditioning coil casing. DO NOT cut

main furnace casing to attach supply side air duct, humidifier, or
other accessories. All accessories MUST be connected to duct

external to furnace casing.
Return Air Connections

FIRE HAZARD
Failure to follow this warning could cause personal injury,

death and/or property damage.
Never connect return--air ducts to the back of the furnace.

Follow instructions below.

!

WARNING

Downflow Furnaces
The return--air duct must be connected to return--air opening
(bottom inlet) as shown in Fig. 1. DO NOT cut into casing sides

(left or right). Side opening is permitted for only upflow and most
horizontal furnaces. Bypass humidifier connections should be

made at ductwork or coil casing sides exterior to furnace. (See

Fig. 19.) Upflow and Horizontal Furnaces The return--air duct
must be connected to bottom, sides (left or right), or a

combination of bottom and side(s) of main furnace casing as
shown in Fig. 1. Bypass humidifier may be attached into unused

return air side of the furnace casing. (See Fig. 18 and 20.) Not all

horizontal furnaces are approved for side return air connections.
(See Fig. 20.)
GAS PIPING

FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal

injury, death, and/or property damage.
Never purge a gas line into a combustion chamber. Never

test for gas leaks with an open flame. Use a commercially

available soap solution made specifically for the detection

of leaks to check all connections.

!

WARNING

FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal

injury, death, and/or property damage.
Use proper length of pipe to avoid stress on gas control

manifold and a gas leak.

!

WARNING

FIRE OR EXPLOSION HAZARD
Failure to protect gas valve inlet from water and debris

could result in death, personal injury and/or property

damage.
Gas valve inlet and/or inlet pipe must remain capped until

gas supply line is permanently installed to protect the valve

from moisture and debris. Also, install a sediment trap in the

gas supply piping at the inlet to the gas valve.

!

WARNING

312A