Chimney inspection chart, 312a – Bryant 2-stage Deluxe Induced-Combustion 4-way Multipurpose 120 User Manual

Page 28

Advertising
background image

28

CHIMNEY INSPECTION CHART

For additional requirements refer to the National Fuel Gas Code NFPA 54/ANSI Z223.1 and ANSI/NFPA 211

Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances in the U.S.A. or to the Canadian

installation Code CSA-B149.1 in Canada.

Consult

Part C of

chimney adapter venting

instructions for

application

suitability

Is chimney

lined with properly

sized, listed liner or

Type-B vent?

Is chimney

to be dedicated to

a single

furnace?

Chimney

exposed to

outdoors below

roof line?

Repair

liner or top seal

or reline chimney as

necessary.

Mortar

or tile

debris?

Clay

tile misalignment,

missing sections,

gaps?

Debris

in cleanout?

Mortar, tile, metal vent,

fuel oil residue?

Is

liner and top

seal in good

condition?

Is chimney

property lined with

clay tile liner?

Crown

condition:

Missing mortar

or brick?

Rebuild

crown.

Yes

Yes

No

No

No

Reline

Yes

Repair

Yes

Yes

Yes

No

No

Remove mortar

and tile debris

Remove metal vent

or liner.

No

No

No

No

Yes

Yes

Suitable

Suitable

Not Suitable

Line chimney with property

sized, listed flexible metal

liner or Type-B vent per

NFGC or NSCNGPIC Vent

Sizing Tables and liner or

vent manufacturer’s

Installation instructions.

Install chimney

adapter per

instructions.

Chimney is

acceptable for use.

Install chimney

adapter per

instructions.

Consult

Part B of

chimney adapter venting

instructions for

application

suitability.

Yes

Not Suitable

Condensate

drainage at bottom

of chimney?

Yes

No

A03206

Fig. 35 -- Chimney Inspection Chart

312A

Advertising