49

CLEANING AND/OR REPLACING AIR FILTER
The air filter arrangement will vary depending on the application.
NOTE: If the filter has an airflow direction arrow, the arrow
must point towards the blower.

CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care

and wear appropriate protective clothing, safety glasses and

gloves when handling parts and servicing furnaces.

CAUTION

!

Media cabinet filter procedures:
NOTE: Media Cabinet is included with two--stage furnace.

Table 17 – Filter size information (in.)

FURNACE

CASING

WIDTH

FILTER SIZE

FILTER TYPE

Side Return

Bottom Re-

turn

14---1/2

16 X 25 X 1

14 X 25 X 1

Cleanable*

17---1/2

16 X 25 X 1

16 X 25 X 1

Cleanable*

21

16 X 25 X 1

20 X 25 X 1

Cleanable*

24

16 X 25 X 1

24 X 25 X 1

Cleanable*

*Recommended

1. Turn off electrical supply to furnace before removing filter

access door.

2. Remove filter cabinet door.
3. Slide filter out of cabinet.
4. If equipped with permanent, washable 1--in filter, clean

filter by spraying cold tap water through filter in opposite

direction of airflow. Rinse filter and let dry. Oiling or
coating of the filter is not recommended. See Table 17 for
size information.

5. If equipped with factory--specified disposable media filter,

replace only with media filter having the same part

number and size. For expandable replacement media, refer
to the instructions included with the replacement media. If
equipped with accessory KGAFR0301ALL external filter

rack. See Table 17.

6. Slide filter into cabinet.
7. Replace filter cabinet door.
8. Turn on electrical supply to furnace.

BLOWER MOTOR AND WHEEL

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal

injury or death.
Blower access door switch opens 115--v power to control.

No component operation can occur unless switch is closed.

Caution must be taken when manually closing this switch

for service purposes.

!

WARNING

NOTE: The blower wheel should not be dropped or bent as
balance will be affected.

The following steps should be performed by a qualified

service agency.
To ensure long life and high efficiency, clean accumulated dirt
and grease from blower wheel and motor annually.
The inducer and blower motors are pre--lubricated and require no

additional lubrication. These motors can be identified by the
absence of oil ports on each end of the motor.
Clean blower motor and wheel as follows:

1. Turn off electrical supply to furnace.
2. Loosen the thumbscrew from outer door and remove outer

door.

3. For downflow or horizontal furnaces having vent pipes

within the furnace that pass in front of the blower access
door:

a. Disconnect vent connector from furnace vent elbow.

b. Disconnect and remove short piece of vent pipe from

within furnace.

4. Remove 2 screws from blower access door and remove

blower access door.

5. Disconnect blower leads from furnace control. Record

wire color and location for reassembly. All other factory

wires can be left connected, but field thermostat
connections may need to be disconnected depending on

their length and routing.

6. Remove 2 screws holding control box to blower shelf.
7. Hang control box from front of furnace casing and away

from blower compartment.

8. Remove 2 screws holding blower assembly to blower

deck and slide blower assembly out of furnace.

9. Clean blower wheel and motor using a vacuum with soft

brush attachment. Blower wheel blades may be cleaned

with a small paint or flux brush. Do not remove or disturb
balance weights (clips) on blower wheel blades.

10. Vacuum any loose dust from blower housing, wheel and

motor.

11. If a greasy residue is present on blower wheel, remove

wheel from the blower housing and wash it with an
appropriate degreaser. To remove wheel:

NOTE: Before disassembly, mark blower mounting arms, motor,
and blower housing so motor and each arm is positioned at the
same location during reassembly.

a. Disconnect capacitor wires (if equipped) and ground wire

attached to blower housing.

b. Remove screws securing cutoff plate and remove cutoff

plate from housing.

c. Loosen set screw holding blower wheel on motor shaft

(160+/--20 in.--lb. when reassembling).

d. Remove bolts holding motor to blower housing and slide

motor out of wheel (40+/--10 in.--lb. when reassembling).

e. Remove blower wheel from housing.

f. Clean wheel and housing.

12. Reassemble motor and blower by reversing steps 11e,

through 11a. Be sure to reattach ground wire to the blower

housing.

13. Verify that blower wheel is centered in blower housing

and set screw contacts the flat portion of the motor shaft.
Loosen set screw on blower wheel and reposition if
necessary.

14. Spin the blower wheel by hand to verify that the wheel

does not rub on the housing.

15. Reinstall blower assembly in furnace.

312A