Warning – Bryant 2-stage Deluxe Induced-Combustion 4-way Multipurpose 120 User Manual

Page 9

Advertising
background image

9

1 SQ IN.

PER

4000

BTUH*

DUCTS

TO

OUTDOORS

1 SQ IN.

PER 4000

BTUH*

CIRCULA

TING

AIR DUCTS

VENT

THROUGH

ROOF

D

B

A

C

E

1 SQ IN.

PER 4000

BTUH*

DUCT

TO

OUTDOORS

CIRCULATING AIR DUCTS

1 SQ IN.

PER 2000

BTUH*

1 SQ IN.

PER 2000

BTUH*

DUCTS

TO

OUTDOORS

12″ MAX

12″ MAX

12″ MAX

Use any of the following

combinations of openings:

A & B C & D D & E F & G

NOTE:

*Minimum dimensions of 3 in.

12″

MAX

12″

MAX

OUTDOORS

1 SQ IN.

PER

4000

BTUH*

F

G

CLEAR

ANCE IN FRONT

OF COMB

USTION AIR

OPENINGS SHALL BE

AT LEAST 3 IN.

A03174

Fig. 7 -- Air for Combustion, Ventilation and Dilution for

Outdoors

The opening shall commence within 12 in. (300 mm) of the
ceiling. Appliances in the space shall have clearances of at least 1

in. (25 mm) from the sides and back and 6 in. (150 mm) from the

front. The opening shall directly communicate with the outdoors
or shall communicate through a vertical or horizontal duct to the

outdoors or spaces (crawl or attic) that freely communicate with
the outdoors.
Indoor Combustion AirE NFPA & AGA Standard and
Known--Air--Infiltration Rate Methods
Indoor air
is permitted for combustion, ventilation, and dilution,
if the Standard or Known--Air--Infiltration Method is used.

CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in death and/or

personal injury.
Many homes require air to be supplied from outdoors for

furnace combustion, ventilation, and dilution of flue gases.

The furnace combustion air supply must be provided in

accordance with this instruction manual.

!

WARNING

CIRCULATING AIR

DUCTS

6" MIN

(FRONT)

CIRCULATING AIR DUCTS

VENT THROUGH ROOF

1 SQ IN.

PER 1000

BTUH* IN DOOR

OR WALL

12" MAX

1 SQ IN.

PER 1000

BTUH* IN DOOR

OR WALL

12" MAX

* Minimum opening size is 100 sq in. with

minimum dimensions of 3 in.

Minimum of 3 in. . when type-B1 vent is used.

UNCONFINED

SPACE

INTERIOR

HEATED

SPACE

CLEARANCE IN FRONT OF COMBUSTION AIR

OPENINGS

SHALL

B

E A

T

LEAST 3 IN.

A03175

Fig. 8 -- Air for Combustion, Ventilation, and Dilution from

Indoors

The Standard Method:

1. The space has no less volume than 50 cubic feet per 1,000

Btuh of the maximum input ratings for all gas appliances
installed in the space and

2. The air infiltration rate is not known to be less than 0.40

air changes per hour (ACH).

The Known Air Infiltration Rate Method shall be used, if the

infiltration rate is known to be:

1. Less than 0.40 ACH and
2. Equal to or greater than 0.10 ACH

Infiltration rates greater than 0.60 ACH shall not be used. The

minimum required volume of the space varies with the number of

ACH and shall be determined per Table 3 or Equations 1 and 2.
Determine the minimum required volume for each appliance in

the space and add the volumes together to get the total minimum
required volume for the space.