Warning, Caution – Bryant 2-stage Deluxe Induced-Combustion 4-way Multipurpose 120 User Manual

Page 21

Advertising
background image

21

115-VOLT FIELD-

SUPPLIED

FUSED

DISCONNECT

JUNCTION

BOX

CONTROL

BOX

24-VOLT

TERMINAL

BLOCK

THREE-WIRE

HEATING-

ONLY

FIVE

WIRE

NOTE 2

NOTE 1

1-STAGE

THERMOSTAT

TERMINALS

FIELD-SUPPLIED

FUSED DISCONNECT

CONDENSING

UNIT

FURNACE

COM

R

W

C

Y

R

G

GND

GND

FIELD 24-VOLT WIRING

FIELD 115-, 208/230-, 460-VOLT WIRING

FACTORY 24-VOLT WIRING

FACTORY 115-VOLT WIRING

Connect Y/Y2-terminal as shown for proper operation.

Some thermostats require a "C" terminal connection as shown.

If any of the original wire, as supplied, must be replaced, use

same type or equivalent wire.

208/230- OR

460-VOLT

THREE

PHASE

208/230-

VOLT

SINGLE

PHASE

WHT

BLK

WHT

BLK

W/W1

W2

Y/Y2

G

NOTES: 1.

2.

3.

A95236

Fig. 24 -- Field Wiring Diagram

Piping should be pressure and leak tested in accordance with
NFGC in the United States or CAN/CSA--B149.1--05 in Canada,

local, and national plumbing and gas codes before the furnace has
been connected. After all connections have been made, purge

lines and check for leakage at furnace prior to operating furnace.
If pressure exceeds 0.5 psig (14--in. wc), gas supply pipe must be
disconnected from furnace and capped before and during supply

pipe pressure test. If test pressure is equal to or less than 0.5 psig
(14--in. wc), turn off electric shutoff switch located on furnace gas

control valve and accessible manual equipment shutoff valve

before and during supply pipe pressure test. After all connections
have been made, purge lines and check for leakage at furnace

prior to operating furnace.
The gas supply pressure shall be within the maximum and

minimum inlet supply pressures marked on the rating plate with

the furnace burners ON and OFF.
ELECTRICAL CONNECTIONS

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal

injury or death.
Blower access panel door switch opens 115--v power to

control. No component operation can occur. Do not bypass

or close switch with panel removed.

!

WARNING

See Fig. 24 for field wiring diagram showing typical field 115--v

wiring. Check all factory and field electrical connections for
tightness.
Field--supplied wiring shall conform with the limitations of 63_F

(33_C) rise.

ELECTRICAL SHOCK AND FIRE HAZARD
Failure to follow this warning could result in personal

injury, death, or property damage.
The cabinet MUST have an uninterrupted or unbroken

ground according to NEC ANSI/NFPA 70--2006 and

Canadian Electrical Code CSA C22.1 or local codes to

minimize personal injury if an electrical fault should occur.

This may consist of electrical wire, conduit approved for

electrical ground or a listed, grounded power cord (where

permitted by local code) when installed in accordance with

existing electrical codes. Refer to the power cord

manufacturer’s ratings for proper wire gauge. Do not use

gas piping as an electrical ground.

!

WARNING

FURNACE MAY NOT OPERATE HAZARD
Failure to follow this caution may result in intermittent

furnace operation.
Furnace control must be grounded for proper operation or

else control will lock out. Control must remain grounded

through green/yellow wire routed to gas valve and manifold

bracket screw.

CAUTION

!

115--V WIRING
Verify that the voltage, frequency, and phase correspond to that

specified on unit rating plate. Also, check to be sure that service
provided by utility is sufficient to handle load imposed by this

equipment. Refer to rating plate or Table 7 for equipment
electrical specifications.

312A