Protective
Operation

Output is shut
OFF and motor
coasts to a
stop.

CPF-05
AD converter fault is detected

Cycle power.
If the fault remains
replace the inverter.

CPF-06
• Option card connecting

fault

• A non-corresponding option

card is connected.

Remove power to the
inverter.
Check the connection
of the digital operator.
Verify inverter software
number (n179).

CPF-07
Operator control circuit
(EEPROM or AD converter)
fault

Cycle power after
checking the digital
operator is securely
mounted.
If the fault remains,
replace the digital
operator or inverter.

Communication option card
self diagnostic error

Option card fault

Replace the option
card.

Communication option card
model code error

Communication option card
DPRAM error

OPR (Operator connecting

fault)

Cycle power.
If the fault remains,
replace the inverter.

CE (MEMOBUS

communications fault)

Check the
communication devices
or communication
signals.

Alarm Display

Inverter

Status

Explanation

Causes and

Corrective Actions