Simple Data Setting

Digital setting (Refer to 5, OPERATING THE INVERTER) and potentiometer setting
are both available for simple accel/decel operation of the VS-606V7.

Frequency reference by analog voltage is set with initial setting (n004 = 1). For the
model with digital operator (with potentiometer) JVOP-140, factory setting is set by
frequency setting potentiometer (n004=0).

Following is an example in which the function LED’s are used to set frequency
reference, acceleration time, deceleration time, and motor direction.

Data setting by frequency setting potentiometer

Status indicator lamp

Operation Steps

Operator

Display

12-LED
Display

Status

Indicator LED

1. Turn the potentiometer fully to the left. Then, turn

the power ON.

0.00

RUN

ALARM

2. F/R blinks.
Select FWD/REV run using keys.

Never select REV when reverse run is

prohibited.

FOR
or
REV

RUN

ALARM

3. Press DSPL to blink FREF. Then press RUN.

0.00

RUN

ALARM

4. Operates the motor by turning the potentiometer

to the right. (Frequency reference corresponds to
the potentiometer position is displayed.)

If the potentiometer is switched rapidly,
the motor also accelerates or decelerates
rapidly corresponding to the
potentiometer movement. Pay attention

to load status and switch the

potentiometer movement.

00.0 to
60.00
Minimum
output
frequency is
1.50Hz

RUN

ALARM

FREF

F/R

FREF

NOTE

FREF

: ON

: Blinking

:OFF

: Blinking (Long Blinking)