IDEX Health & Science VS-606V7 Series User Manual

Page 157

Advertising
background image

157

Second Functions (Parameters n050 to n079)

No.

Register

No. for

Trans-

mission

Name

Setting Range

Setting

Unit

Initial

Setting

User

Setting

Ref.

Page

050

0132

Multi-function input
selection 1

1 to 25,26

(Note 8)

1

1

74

051

0133

Multi-function input
selection 2

1 to 25,26

(Note 8)

1

2

74

052

0134

Multi-function input
selection 3

0 to 25,26

(Note 8)

1

3

74

053

0135

Multi-function input
selection 4

1 to 25,26

(Note 8)

1

5

74

054

0136

Multi-function input
selection 5

1 to 25,26

(Note 8)

1

6

74

055

0137

Multi-function input
selection 6

1 to 25,26

(Note 8)

1

7

74

056

0138

Multi-function input
selection 7

1 to 25, 26, 34,

35 (Note 8)

1

10

74

057

0139

Multi-function output
selection 1

0 to 7, 10 to 19,

20, 21

(Note 8)

1

0

82

058

013A

Multi-function output
selection 2

0 to 7, 10 to 19,

20, 21

(Note 8)

1

1

82

059

013B

Multi-function output
selection 3

0 to 7, 10 to 19,

20, 21

(Note 8)

1

2

82

060

013C

Analog frequency
reference gain (FR)

0 to 255%

1%

100%

52

061

013D

Analog frequency
reference bias (FR)

-100 to 100%

1%

0%

52

062

013E

Analog frequency
reference filter time
parameter (FR)

0.00 to 2.00s

0.01s

0.10s

---

064

0140

Operation select for
frequency reference loss
(Note 9)

0,1

1

0

---

065

0141

Monitor output selection

0,1

1

0

66

066

0142

Monitor item selection

0 to 5

1

0

65

067

0143

Monitor gain

0.00 to 2.00

0.01

1.00

65

068

0144

Analog frequency
reference gain
(CN2 V

in

)

-255 to 255%

1%

100%

79

069

0145

Analog frequency
reference bias
(CN2 V

in

)

-100 to 100%

1%

0%

79