IDEX Health & Science VS-606V7 Series User Manual

Page 164

Advertising
background image

164

151

0197

Timeover detection
selection

0 to 4

1

0

94

152

0198

Setting unit selection of
communications
frequency reference/
frequency monitor

0, 1, 2, 3

1

0

94

153

0199

Slave address

0 to 32

1

0

94

154

019A

Baud rate selection

0 to 3

1

2

94

155

019B

Parity selection

0, 1, 2

1

2

94

156

019C

Send waiting time

10 to 65ms

1ms

10ms

94

157

019D

RTS control

0, 1

1

0

94

158

019E

Motor code (energy-
saving control)

0 to 70

1

(Note 7)

105

159

019F

Energy-saving voltage
upper limit (at 60Hz)

0 to 120%

1%

120%

106

160

01A0

Energy-saving voltage
upper limit (at 6Hz)

0 to 25%

1%

16%

106

161

01A1

Search operation power
detection hold width

0 to 100%

1%

10%

108

162

01A2

Power detection filter
time parameter

0 to 255

1 = 4 ms

5 (20ms)

108

163

01A3

PID output gain

0.0 to 25.0

0.1

1.0

113

164

01A4

PID feedback selection

0 to 5

1

0

110

165

01A5

Overheat protect select
for installed braking
resistor (Note 9)

0,1

1

0

61

166

01A6

Input open-phase
detection level (Note 9)

0 to 100%

1%

0%

---

167

01A7

Input open-phase
detection time (Note 9)

0 to 255,s

1,s

0,s

---

168

01A8

Output open-phase
detection level (Note 9)

0 to 100%

1%

0%

---

169

01A9

Input open-phase
detection time (Note 9)

0 to 2,0,s

0.1,s

0.0,s

---

175

#1
#2

01AF

Reducing carrier
frequency selection at
low speed

0,1

1

0

(Note 10)

70

176

01B0

Parameter copy
selection

rdy,rEd,CPy

vFy,vA,Sno

---

rdy

116

177

01B1

Prohibiting parameter
read selection

0,1

1

0

117

178

01B2

Fault history

Stores,

displays most

recent 4

alarms

Setting

disabled

36

179

01B3

Software No.

Displays lower-

place 4 digits

of software No.

Setting

disabled

No.

Register

No. for

Trans-

mission

Name

Setting Range

Setting

Unit

Initial

Setting

User

Setting

Ref.

Page