O

th

e

r F

u

nc

ti

ons

Di

spl

a

y

Status Indicator LED

RUN and ALARM provided as standard LEDs

Digital Operator

(JVOP-140)

Available to monitor frequency reference, output
frequency, output current

Terminals

Main circuit: screw terminals
Control circuit: plug-in screw terminal

Wiring Distance between

Inverter and Motor

328ft (100m) or less#

Enclosure

Open chassis IP20, Open chassis IP20 (Top-closed type),
or enclosed wall-mounted NEMA 1

Cooling Method

Cooling fan is provided for the following models: 400V,
1.5kW or larger inverters (3-Phase)
Others models are self-cooling

E

n

v

iron

m

ent

al

Con

d

it

ions

Ambient Temperature

Open chassis IP20 : -10 to +50

°

C (14 to 122

°

F)

Open chassis IP20 (Top-closed type) and enclosed
wall mounted NEMA1. : -10 to +40

°

C (14 to 105

°

F)

(not frozen)

Humidity

95% RH or less (non-condensing)

Storage Temperature*

-4 to 140

°

F (-20 to +60

°

C)

Location

Indoor (free from corrosive gases or dust)

Elevation

3280ft (1000m) or less

Vibration

Up to 9.8m / S

2

(1G) at less than 20Hz, up to 2m / S

2

(0.2G) at less than 20 to 50Hz

* Temperature during shipping (for short period)
# For details, refer to “Reducing motor noise or leakage current (n080)” on

page 68.

Voltage Class

400V 3-phase

Model

CIMR-V7*C

‰‰‰‰

3-phase

40P2 40P4 40P7 41P5 42P2 43P0 43P7 45P5 47P5

Single-phase