n115 setting

Accel/decel time selection during stall prevention (n116)

With this function, acceleration/deceleration time when moving to prevent stalling

during operations can be assigned to the two parameters, n021 and n022.

n116 setting

Stall prevention (current limit) function during acceleration (n092)

To prevent over voltage during deceleration, the inverter automatically extends the

deceleration time according to the value of the main circuit DC voltage. When
using an optional braking resistor, set n092 to 1.

Setting

Function

0

The stall prevention level becomes the level set for the parameter n094 in all frequency areas

1

The following shows that the stall prevention level is automatically decreased in the parameter output
range (Max. frequency>Max. voltage output frequency).
The lower limit is 40% of the set value of n094.

Parameter

No.

Name

Unit

Setting Range

Initial Setting

n116

Accel/decel time selection
during stall prevention

-

0=Disabled
1=Enabled

0

Setting

Function

0

Accel/decel time is set by accel/decel time 1or 2.

1

Accel/decel time is fixed at accel/decel time 2(n021, n022)

Setting

Stall prevention (current limit) during

deceleration

0

Provided

1

Not provided (when braking resistor is mounted

Advertising