IDEX Health & Science VS-606V7 Series User Manual

Page 165

Advertising
background image

165

Notes: 1.

Not initialized by parameter initalization.

2.

Upper limit and initial setting of setting range are doubled at 400 class.

3.

Changes depending on inverter capacity. Refer to the next page.

4.

Changes depending on inverter capacity. Refer to page 64.

5.

Initial setting of the model with operator JVOP-140 (with potentiometer)
is 0. Setting can be set to 1 by parameter initialization.

6.

When control mode selection (n002) is changed, initial setting
correspondents to the control mode.

7.

Changes depend on inverter capacity. Refer to page 101.

8.

Setting value only applies to 200/400V class 7.5/10hp (5.5/7.5kW)
inverters.

9.

Parameter value only applies to 200/400V class 7.5/10hp (5.5/7.5kW)
inverters

10. “1” for 200/400V class 7.5/10hp (5.5/7.5kW) inverters

* Values are double with 400V class.

Initial settings that change with inverter capacity

200V class 3-phase

No.

Name

V / f control mode

(n002 = 0)

Vector control mode

(n002 = 1)

n014

Mid. output frequency

1.3Hz

3.0Hz

n015

Mid. output frequency voltage

12.0V*

11.0V*

n016

Minimum output frequency

1.3Hz

1.0Hz

n017

Minimum output frequency voltage

12V*

4.3V*

n104

Torque compensation time parameter

0.3s

0.2s

n111

Slip compensation gain

0.0

1.0

n112

Slip compensation gain time parameter

2.0s

0.2s

No.

Name

Unit

Factory setting

Inverter capacity

kW 0.1kW 0.25kW 0.55kW 1.1kW 1.5kW 2.2kW

3.7kW 5.5kW 7.5kW

n036 Motor rated current

A

0.6

1.1

1.9

3.3

6.2

8.5

14.1

19.6

26.6

n105

Torque
compensation iron
loss

W

1.7

3.4

4.2

6.5

11.1

11.8

19

28.8

43.9

n106 Motor rated slip

Hz

2.5

2.6

2.9

2.5

2.6

2.9

3.3

1.5

1.3

n107

Motor resistance for
one phase*

17.99

10.28

4.573

2.575

1.233

0.8

0.385

0.199

0.111

n108

Motor leakage
inductance

MH

110.4

56.08

42.21

19.07

13.4

9.81

6.34

4.22

2.65

n110

Motor no-load
current

%

72

73

62

55

45

35

32

26

30