ElmoMC ExtrIQ Digital Servo Drives-Eagle HV User Manual

Page 27

Advertising
background image

Eagle HV Installation Guide

Installation

MAN-EAG-HVIG (Ver. 1.502)

www.elmomc.com

27

For non-S 400 VDC type drives:

Pin Function

Cable

Pin Positions

VP+ Pos. Power input

DC Power

VN- Neg. Power input

DC Power

N N/A

N/A

PE Protective earth

DC Power

AC Motor

Cable

DC Motor

Cable

PE Protective earth

Motor

Motor

M1 Motor phase

Motor

N/C

M2 Motor phase

Motor

Motor

M3 Motor phase

Motor

Motor

Auxiliary 24 VDC Backup Supply
(CAN connector)

VL- N.C.

VL+ N.C.

Table 5: Connectors for Main DC Power and Motor Cable – in Non-S 400 VDC Type Drives