Auxiliary supply (only for s type drive), Environmental conditions – ElmoMC ExtrIQ Digital Servo Drives-Eagle HV User Manual
Page 75
Eagle HV Installation Guide
Technical Specifications
MAN-EAG-HVIG (Ver. 1.502)
75
4.6. Auxiliary Supply (Only for S type drive)
Feature
Details
Auxiliary power supply
Isolated DC source only
Auxiliary supply input voltage
18 VDC to 30 VDC
Auxiliary supply input power
7 VA
Note:
An S type drive can only operate if it has an auxiliary supply.
4.7. Environmental Conditions
Feature
Operation Conditions
Range
Ambient
Temperature
Range
Non-operating conditions -50 °C to +100 °C (-58 °F to 212 °F)
Operating conditions
-40 °C to +71 °C (-40 °F to 160 °F)
Temperature
Shock
Non-operating conditions -40 °C to +71 °C (-40 °F to 160 °F) within
3 min.
Altitude
Non-operating conditions Unlimited
Operating conditions
-400 m to 12,000 m (-1312 to 39370 feet)
Humidity
Non-operating conditions Up to 95% non-condensing humidity at 35 °C
(95 °F)
Operating conditions
Up to 95% non-condensing humidity at 25 °C
(77 °F), up to 90% non-condensing humidity at
42 °C (108 °F)
Vibration
Operating conditions
20 Hz to 2000 Hz, 14.6 g
Mechanical
Shock
Non-operating conditions ±40g; Half sine, 11 msec
Operating conditions
±20g; Half sine, 11 msec