Auxiliary supply (only for s type drive), Environmental conditions – ElmoMC ExtrIQ Digital Servo Drives-Eagle HV User Manual

Page 75

Advertising
background image

Eagle HV Installation Guide

Technical Specifications

MAN-EAG-HVIG (Ver. 1.502)

www.elmomc.com

75

4.6. Auxiliary Supply (Only for S type drive)

Feature

Details

Auxiliary power supply

Isolated DC source only

Auxiliary supply input voltage

18 VDC to 30 VDC

Auxiliary supply input power

7 VA

Note:

An S type drive can only operate if it has an auxiliary supply.

4.7. Environmental Conditions

Feature

Operation Conditions

Range

Ambient

Temperature

Range

Non-operating conditions -50 °C to +100 °C (-58 °F to 212 °F)

Operating conditions

-40 °C to +71 °C (-40 °F to 160 °F)

Temperature

Shock

Non-operating conditions -40 °C to +71 °C (-40 °F to 160 °F) within

3 min.

Altitude

Non-operating conditions Unlimited

Operating conditions

-400 m to 12,000 m (-1312 to 39370 feet)

Humidity

Non-operating conditions Up to 95% non-condensing humidity at 35 °C

(95 °F)

Operating conditions

Up to 95% non-condensing humidity at 25 °C
(77 °F), up to 90% non-condensing humidity at
42 °C (108 °F)

Vibration

Operating conditions

20 Hz to 2000 Hz, 14.6 g

Mechanical

Shock

Non-operating conditions ±40g; Half sine, 11 msec

Operating conditions

±20g; Half sine, 11 msec

Advertising