Auxiliary feedback port (output mode ya[4]= 4) – ElmoMC ExtrIQ Digital Servo Drives-Eagle HV User Manual
Page 82
Eagle HV Installation Guide
Technical Specifications
MAN-EAG-HVIG (Ver. 1.502)
82
4.9.4.
Auxiliary Feedback Port (output mode YA[4]= 4)
Feature
Details
Emulated output
•
A, B, Index
•
Differential outputs
Output current capability
Maximum output current: I
OH
(max) = 2 mA
High level output voltage: V
OH
> 3.0 V
Minimum output current: I
OL
= 2 mA
Low level output voltage: V
OL
< 0.4 V
Available as options
•
Emulated encoder outputs of analog encoder
•
Emulated encoder outputs of the resolver
•
Emulated encoder outputs of the tachometer
•
Emulated encoder outputs of the potentiometer
Maximum frequency
f
MAX
: 5 MHz pulses/output
Edge separation between A & B
Programmable number of clocks to allow adequate
noise filtering at remote receiver of emulated encoder
signals
Index (marker):
Length of pulse is one quadrature (one quarter of an
encoder cycle) and synchronized to A&B
Figure 32: Auxiliary Feedback - Encoder Phase Diagram