Eagle HV Installation Guide

Technical Specifications

MAN-EAG-HVIG (Ver. 1.502)

www.elmomc.com

82

4.9.4.

Auxiliary Feedback Port (output mode YA[4]= 4)

Feature

Details

Emulated output

A, B, Index

Differential outputs

Output current capability

Maximum output current: I

OH

(max) = 2 mA

High level output voltage: V

OH

> 3.0 V

Minimum output current: I

OL

= 2 mA

Low level output voltage: V

OL

< 0.4 V

Available as options

Emulated encoder outputs of analog encoder

Emulated encoder outputs of the resolver

Emulated encoder outputs of the tachometer

Emulated encoder outputs of the potentiometer

Maximum frequency

f

MAX

: 5 MHz pulses/output

Edge separation between A & B

Programmable number of clocks to allow adequate
noise filtering at remote receiver of emulated encoder
signals

Index (marker):

Length of pulse is one quadrature (one quarter of an
encoder cycle) and synchronized to A&B

Figure 32: Auxiliary Feedback - Encoder Phase Diagram