Eagle HV Installation Guide

Installation

MAN-EAG-HVIG (Ver. 1.502)

www.elmomc.com

31

3.5.3.3.a

Three-Phase Direct-to-Mains Connection Topology

Figure 6: Non-Isolated Three-Phase Connection Topology

Caution:

Do not connect VN- to PE. In a direct-to-mains connection the VN- must

not be connected to the PE. Connecting the VN- to the PE will cause
irreparable damage to the system.

Be careful and note that in a direct-to-mains connection the Neutral point

is not the most negative voltage level. It is the mid-point level of the
rectified DC bus.

3.5.3.3.b

Single-Phase Direct-to-Mains Connection Topology

Figure 7: Non-Isolated Single-Phase Connection Topology