Eagle HV Installation Guide

Technical Specifications

MAN-EAG-HVIG (Ver. 1.502)

www.elmomc.com

84

4.10. I/Os

The Eagle HV has:

6 Digital Inputs

4 Digital Outputs

1 Analog Input

4.10.1. Digital Input Interfaces

Feature

Details

Type of input

Optically isolated

PLC level as default or TTL option upon request

Input current
for all inputs

Rin=3.43K, Iin = 1.2 mA @ Vin = 5 V
Rin=3.43K, Iin = 6.7 mA @ Vin = 24 V

High-level input voltage

5 V < Vin < 24 V

Low-level input voltage

0 V < Vin < 1 V

Minimum pulse width

> 4 x TS, where TS is sampling time

Execution time (all inputs):
the time from application of
voltage on input until execution
is complete

If input is set to one of the built-in functions — Home,
Inhibit, Hard Stop, Soft Stop, Hard and Soft Stop,
Forward Limit, Reverse Limit or Begin — execution is
immediate upon detection: 0<T<4xTS
If input is set to General input, execution depends on
program. Typical execution time: ≅ 0.5 msec.

High-speed inputs – 5 & 6
minimum pulse width, in high-
speed mode

T < 5 µsec

Notes:

Home mode is high-speed mode and can be used for

fast capture and precise homing.

High speed input has a digital filter set to same value

as digital filter (EF) of main encoder.

Highest speed is achieved when turning on

optocouplers.

Figure 34: Digital Input Schematic