Eagle HV Installation Guide

Installation

MAN-EAG-HVIG (Ver. 1.502)

www.elmomc.com

36

Figure 11: Feedback and Control Cable Assemblies

Note:

All D-Sub type connectors, used with the Eagle HV, should be assembled in this way.

3.5.6.

Main Feedback Cable (Feedback A)

The main feedback cable is used to transfer feedback data from the motor to the drive.

The Eagle HV can accept any one the following devices as a main feedback mechanism:

Incremental encoder only

Incremental encoder with digital Hall sensors

Digital Hall sensors only

Interpolated Analog (Sine/Cosine) encoder (option)

Resolver (option)

Tachometer (option)

Potentiometer (option)

Absolute Encoder

FEEDBACK A of the Eagle HV has a high density 15-pin D-Sub socket. Connect the Main
Feedback cable from the motor to FEEDBACK A using a 15-pin, D-Sub plug with a metal
housing. When assembling the Main Feedback cable, follow the instructions in Section 3.5.5
(Feedback and Control Cable Assemblies).

Make sure that the

braid shield is in tight
contact with the metal

housing

Connector

body

Drain wire

soldered to

the metal

housing

Advertising