Isync, Itype, Isync itype – Barco DCS-200 User Manual

Page 145: K==oéãçíé=`зенкзд

Advertising
background image

DCS-200 • User’s Guide

145

_K==oÉãçíÉ=`зенкзд

Remote Commands

List Format: Each input type has a different list of valid sample modes.

ISMP -i (input) --list

List Response: 0:"OverSample"

1:"1:1"

fpvk`

Description: Input Sync Type Adjust. This command is only valid for analog
input types.

Command Format: ISYNC -i (input) -s (sync)

Parameters: -i (input): 1 - 8 (7 & 8 only if itype is analog)

-s (sync): 0 - auto, 1 - H/V, 2- CSync, 3- SOG (Default: auto)

Query Format: ISYNC -i (input) -?

Query Response: ISYNC -i (input) -s(sync) --min 0 --max 3

List Format: ISYNC -i (input) --list

List Response: 0:"AUTO"

1:"H/V"

2:"CSYNC"

3:"SOG"

fqvmb

Description: Input Type Adjust. This command is only adjustable for the analog
inputs. Other inputs will provide query information only.

Command Format: ITYPE -i (input) -t (type)

Parameters:

-i (input): 1 - 8 for adjustments (7 & 8 only if itype is analog) ; 1 - 9 for
query

-t (type): 1-analog, 2-Y/C, 3-CVBS, 4-SDI, 5-DVI, 6-YPbPr

Query Format: ITYPE -i (input) -?

Query Response: ITYPE -i (input) -t (type)

List Format: Each input type has a different list of valid input types.

ITYPE -i (input) --list

List Response: 1:"RGB"

2:"Y/C"

3:"CVBS"

4:"SDI"

5:"DVI"

6:"YPbPr"

Advertising