Specifications, Model 505.60–505.180 hpu general specifications, Specifications 32 – MTS Series 505 SilentFlo Hydraulic Power Unit Model 505-180 User Manual

Page 32: Model 505.60–505.180 hpu general specifications 32

Advertising
background image

Model 505.60 - 505.180 SilentFlo™ HPU

32

Specifications

Introduction

Specifications

Model 505.60–505.180 HPU General Specifications

Parameter

Specification

Environmental

Operating temperature

Humidity

For use in a controlled environment.

5–40°C (40–104°F)

0–85% noncondensing

Hydraulic fluid

Typical operating
temperature range

Filtration (microns)

Output Pressure

Non-adjustable relief valve
setting

Exxon Mobil DTE 25 or Shell Tellus 46 AW

43–49°C (110–120°F)

3 microns nominal

21 MPa (3000 psi)

22.4 MPa (3250 psi)

Heat exchanger

Water pressure

Maximum pressure

Water hose (.60/.90)
Water hose (.120/.150/.180)

Typical operating range

Max tempinterlock pre-set

Water-cooled

0.2–0.3 MPa (35–45 psi differential)

0.8 MPa (120 psi)

38 mm (1.5 in) NPT
51 mm (2 in) NPT

43-49°C (110-120°F)

55°C (131°F)

Hydraulic connections

Pressure

Return

Drain

2 inch SAE

2 inch SAE

-16 JIC

Electrical Power

Line voltage

Control voltage

380–575 V AC

24 V DC

Advertising