MTS Series 505 SilentFlo Hydraulic Power Unit Model 505-180 User Manual

Page 80

Advertising
background image

Model 505.60 - 505.180 SilentFlo™ HPU

80

Resetting the Thermal Overloads

Operation

Additional protection is provided by line fuses (FU1–FU9 for the Model 505.60/
.90 and FU1-FU18 for the Model 505.120–.180) and transformer fuses (FU10–
FU12 for the Model 505.60/.90 and FU19–FU21 for the Model 505.120–.180).
These cartridge-type fuses must be replaced with fuses of the same size, type, and
rating, which vary according to the voltage configuration.

A tripped thermal overload or a blown fuse indicates a potential short circuit, too
much heat in the electrical box, or a component failure (mechanical or electrical).

Reset the thermal overload switches or replace the fuses as follows:

1. Turn the main disconnect switch counterclockwise to remove power from

the electrical control box.

2. Loosen the three bolts securing the door of the electrical enclosure and open

the door.

3. Locate the thermal overload switch. Press Reset to clear the switch. If the

thermal overload switch trips again, wait until the switch cools.

Thermal

Overloads

Transformer

Fuses

Line

Fuses