ROD Setup

Model 505.60 - 505.180 SilentFlo™ HPU

Operation

73

To select this screen, press and hold the ROD Setup button for five seconds.

More about ROD setup

To setup the system for run-on-demand you first need to know what your system
flow requirements will be for the full compliment of tests or test systems you will
be using.

For example, you determine that all the tests you expect to be running will
require 70 gpm of hydraulic fluid flow. Therefore you will need three pumps (90
gpm) to meet this demand. Using the ROD startup procedure for the HPU model
you have, you enable the three pumps you want to run that day, setup the ROD
Setup,
and start the HPU under ROD control. The HPU starts with one pump
running (the one with the lowest number of running hours) in high pressure and
the other two in standby mode.

ROD Setup

Control

Descriptions

Minimum # of Pumps on
Startup
display and button

Displays the adjustment range (in pumps) and how many of those pumps will
be running at startup for run-on-demand.

Next Stage On Delay display
and button

Displays the adjustment range (in seconds) for the on delay and the current
delay setting.

The flow must be at or above the trigger level for this amount of time before
the next pump motor will turn on.

Minimum Available Flow
Trigger
display and button

Displays the adjustment range (in gpm and lpm) for the minimum flow trigger
and the current setting for the trigger.

Next Stage Off Delay
display and button

Displays the adjustment range (in minutes) for the off delay and the current
delay setting.

The flow must be below the trigger level for this amount of time before the a
pump motor will turn off.

Rated Full Flow Per Pump
display and button

Displays the adjustment range (in gpm and lpm) for the flow of each pump and
the current full flow setting.

Flow Meter Present or Flow
Meter Not Present
button

If Flow Meter Not Present, no other buttons are displayed on the screen.

Flow Meter Present must be selected to display the buttons on this screen.

Flow Display in gpm or lpm
button

Use this button to select the desired flow units for the HPU displays. Click on
this button to toggle between units: gpm or lpm.

Auto Reset ROD Upon HPU
Stop
or Do Not Reset ROD
Upon HPU Stop
button

Select Auto Reset ROD Upon HPU Stop to disable the Auto Demand
(ROD) button on the Main Panel when you press the Stop button.

Select Do Not Reset ROD Upon HPU Stop to hold the Auto Demand
(ROD) button on the Main Panel enabled when the you push the Stop
button.