Capscrew-style housing filter replacement, Capscrew-style housing filter replacement 96 – MTS Series 505 SilentFlo Hydraulic Power Unit Model 505-180 User Manual

Page 96

Advertising
background image

Model 505.60 - 505.180 SilentFlo™ HPU

96

Capscrew-Style Housing Filter Replacement

Maintenance

6. Replace the O-ring(s) seals in the bypass valve assembly and under the

cover. (Reference MTS part number 100-030-032 and 100-030-053.)

7. Unscrew the “T” handle from the cartridge rod and remove the filter

cartridge.

8. Install a new filter on the cartridge rod and secure it with the “T” handle.

9. Install the filter cartridge assembly into the head assembly and into the filter

tube.

10. Replace the cover and clamp it to the head assembly.

11. Turn on the HPU and switch to high-pressure mode. Inspect the seal

between the housing, filter, and cover for any signs of leakage.

12. If leakage occurs, repeat this procedure (without replacing the filter

element). If leakage persists, contact MTS Systems Corporation.

13. If you are changing the filter because the dirty filter indicator tripped, run

the HPU for two to four hours to remove contaminants. Then take a fluid
sample and have it analyzed.

14. Continue to clean the fluid if it does not meet an ISO cleanliness level of 16/

13/9 or better.

15. Press the Reset button on the user interface panel to reset any interlocks and

turn off the Return Filter Dirty indicator.

Capscrew-Style Housing Filter Replacement

The return-line filter element of the HPU should be replaced for the following
reasons:

When the dirty-filter detector trips

Whenever the hydraulic fluid is changed

The filter manufacturer’s recommended maximum interval (1000 hours or 6
months)

Capscrews (4)
110 N·m (84 lbf·ft)

Filter Cap

Spring

Bypass Valve Assembly

Filter Element

Filter Housing

O-ring

Advertising