Model 505.150 hpu specifications, Model 505.150 hpu specifications 36 – MTS Series 505 SilentFlo Hydraulic Power Unit Model 505-180 User Manual

Page 36

Advertising
background image

Model 505.60 - 505.180 SilentFlo™ HPU

36

Model 505.150 HPU Specifications

Introduction

Model 505.150 HPU Specifications

Parameter

Specification

Pump/Motor

Number of pump/motors

Maximum continuous
pressure

Maximum flow capacity

Motor rating

*

Current draw

*

For one motor

† For all motors

Wye-Delta starter configuration

5

21 MPa (3000 psi)

500 L/m (133 gpm) at 50 Hz
567 L/m (150 gpm) at 60 Hz

45 kW (60 hp) at 50/60 Hz

387 A continuous at 460 V AC 60 Hz
476 A continuous at 380 V AC 50 Hz

Reservoir capacity

1893 L (500 gal) maximum
1211 L (320 gal) minimum

Water flow rating
(input temperature)

10°C (50°F)

15.5°C (60°F)

21.1°C (70°F)

26.7°C (80°F)

32.2°C (90°F)

Heat load (maximum)

87.8 L/m (23.2 gpm)

94.6 L/m (25 gpm)

121.1 L/m (32 gpm)

159.0 L/m (42.0 gpm)

265.0 L/m (70 gpm)

224 kW (765,000 Btu/hr)

Dimensions

Length

Height

Width

4270 mm (168 in)

2006 mm (79 in)

990 mm (39 in)

Weight

Empty

With hydraulic fluid

3313 kg (7305 lb)

4372 kg (9638 lb) minimum fluid level
4979 kg (10977 lb) maximum fluid level

Noise

rating at 1 m

‡ Sound pressure level [dB(A)] is expressed as a free field value.

Readings may vary with the acoustic environment.

71 dB(A) fully compensated

Advertising