Routine Maintenance Overview Checklist

Model 505.60 - 505.180 SilentFlo™ HPU

Maintenance

89

Replace all filters

MTS

MTS

Verify operation and settings
of psi control and relief valves

MTS

MTS

Check pump/motor coupling
for wear and debris

MTS

Check pump voltage and
current

MTS

Check case drain flow

MTS

Recommend MTS Hydraulix
oil sample

MTS

MTS

MTS

MTS

Recommend replacement or
rebuild of heat exchanger

MTS

MTS

Recommend replacement of
hoses

MTS

Recommend replacement of
motor bearings

MTS

MTS

Recommend replacement or
rebuild of pump

MTS

Recommend replacement or
rewind of motor

MTS

Recommend hydraulic fluid
change & clean pump inlet
strainer

MTS

*Symbol denotes services performed by equipment operators. Most of these procedures involve visual checks
that should not interfere with test system operation. These checks are also completed by trained field service
engineers on each Routine Maintenance visit.

†Symbol denotes service performed by trained field service engineers as part of an MTS Routine Maintenance
plan. Some of these procedures require special service tools and/or specific service training to complete.

Recommended service to be performed at each running time interval noted

Calendar Time using 8 hour
Running Time rate per day

Daily

Weekly

Monthly

Annually

Running Time-Hours

8

40

160

500

1000 1,500 2,000