Operation

67

Pump Enable/Disable

The number of buttons displayed is determined by the model of the HPU and
the selection made on the HPU Setup screen.

Pump #1 through 6
Disabled
buttons

Disables the associated pump. The button is green if the pump is disabled.

Pump #1 through 6
Enabled
buttons

Enables the associated pump. The button is green if the pump is enabled.

Hyd Fluid Pressure display

Displays the output pressure (in MPa or psi) of the HPU.

Hyd Fluid Temp display

Displays the temperature (in °F or °C) of the hydraulic fluid in the reservoir.

HPU Run Status

Run Status display

Displays the current run status of the HPU. The status conditions may be:

Off

Run-Low

Run- High

Auto-Mode

Fault Status
display

Displays the current fault status of the HPU. If one or more faults exist, the
button will blink red and the message will alternate between Faulted and the
existing fault conditon(s). The display condition may be:

Normal (steady green)

Faulted

Overtemp

Hyd Fluid Level

Motor Overload

Dirty

Filter

E-stop

Panel selector buttons

Click on a gray button to display the screen for the selection. The selected
button turns white. The screens are described on the following pages.

Reset

The button is blue when all systems are normal.

The button is light blue when an interlock condition exists.

Clears any interlocks caused by the HPU (provided the reason fro the interlock
has been corrected). This switch operates independently from any other reset
functions in your control system.

Main Panel Display Controls (Continued)

Control

Descriptions