Setting Up Run-On-Demand

Operation

5. Check the Rated Full Flow Per Pump.

This value should only require change if the HPU is provided with pumps
that have a different full flow rating.

6. Select as required Auto Reset ROD Upon HPU Stop or Do Not Reset

ROD Upon HPU Stop.

Model 505.60/.90 only

After you have defined the run-on-demand parameters:

1. Press the HPU Data button. On the HPU Data screen, identify the enabled

pump with the least number of hours.

2. Press the Main Display button to return to the Main Display screen.

3. Press the Pump #_ Enabled button for the pump identified in Step 1.

4. Press Run/Low Pressure to start the selected pump in low pressure.

5. Press High Pressure to select high pressure mode.

6. Press and hold the Auto Demand ROD button for five seconds to enable

the run-on-demand option.

7. Press the Pump #_ Enabled button for any other pumps you want running

under run-on-demand control.

8. To disable run-on-demand after it is running, without turning off the HPU,

momentarily pressing the Reset button will disable it.

9. To turn off the HPU and disable run-on-demand pressing the Stop button.

Repeat Steps 3 through 6 to re-enable run-on-demand.

Models 505.120-.180

only

After you have defined the run-on-demand parameters:

1. Press the Main Display button to return to the Main Display screen.

2. Momentarily press the Auto Demand ROD button to enable the run-on-

demand option. The button will turn green.

3. Press the Pump #_ Enabled button for those pumps you want active for

run-on-demand.

4. Press Run/Low Pressure to start the HPU in low pressure.

5. Press High Pressure to select high pressure mode.

The number of pumps running will be determined by the setting on the
ROD Setup screen.

6. To disable run-on-demand after it is running, without turning off the HPU,

momentarily pressing the Reset button will disable it.

7. Pressing the Stop button will:

Turn off the HPU and disable run-on-demand if Auto Reset ROD
Upon HPU Stop
was selected on the ROD Setup screen.

8. Turn off the HPU but leave the run-on-demand enabled if Do Not Reset

ROD Upon HPU Stop was selected on the ROD Setup screen.