Model 505.60 - 505.180 SilentFlo™ HPU

54

Model 505.60 HPU Setup

Installation

5. On the user interface panel, press and hold the HPU Setup button for five

seconds to display the HPU Setup panel.

6. Verify that the correct pumps are present for the HPU model installed.

For Model 505.60, typically two pumps are present (three buttons are
displayed).

For Model 505.90, typically three pumps are present (three buttons are
displayed).

For Model 505.120, typically four pumps are present (six buttons are
displayed).

For Model 505.150, typically five pumps are present (six buttons are
displayed).

For Model 505.180, typically six pumps are present (six buttons are
displayed).

Note

You can use these buttons to intentionally take a pump offline. For
example: in the figure above, pumps #1 through #5 are present (online),
pump #6 is not present (offline). This prevents pump #6 from being
enabled on the Main Panel. Clicking on the Pump #6 Not Present
button will place it online (the button turns green). Clicking on any of the
green Pump Present buttons will take that pump offline.

7. Check and, if desired, change the following selections:

A.

Select your preference for temperature units.

Press the Temp Display button to display the desired units: Temp
Display in °C
or Temp Display in °F.

B.

Select your preference for the hydraulic pressure units:

Press the Pressure Display button to display the desired units:
Pressure Display in MPa or Pressure Display in psi.