Data table structure – Rockwell Automation 1203 Serial Communications Module Series B User Manual

Page 37

Advertising
background image

4–3

Configuring and Interfacing

1203–5.5 September 1995

Data Table Structure

The Serial Communications Module provides the following data
table structures for DF1 and DH–485.

The following table is the drive control table (binary file).

File

Address

Description

File

Address

Description

B3:0

Logic Command

B3:10

Logic Status

B3:1

Reference

B3:11

Feedback

B3:2

Datalink A1 In (to Drive)

B3:12

Datalink A1 Out (from Drive)

B3:3

Datalink A2 In (to Drive)

B3:13

Datalink A2 Out (from Drive)

B3:4

Datalink B1 In (to Drive)

B3:14

Datalink B1 Out (from Drive)

B3:5

Datalink B2 In (to Drive)

B3:15

Datalink B2 Out (from Drive)

B3:6

Datalink C1 In (to Drive)

B3:16

Datalink C1 Out (from Drive)

B3:7

Datalink C2 In (to Drive)

B3:17

Datalink C2 Out (from Drive)

B3:8

Datalink D1 In (to Drive)

B3:18

Datalink D1 Out (from Drive)

B3:9

Datalink D2 In (to Drive)

B3:19

Datalink D2 Out (from Drive)

Note: If you write to B3:0 through B3:9, you will write data to the
drive. If you read from B3:0 through B3:9, you will return the data
being currently sent to the drive. If you read from B3:10 through
B3:19, you will read data from the drive. If you write to B3:10
through B3:19, you will receive an error.

The following table is the drive control table (integer file).

File Address

Description

N41:0

Logic Command/Status

N41:1

Reference/Feedback

N41:2

Datalink A1

N41:3

Datalink A2

N41:4

Datalink B1

N41:5

Datalink B2

N41:6

Datalink C1

N41:7

Datalink C2

N41:8

Datalink D1

N41:9

Datalink D2

Note: If you write to any location in N41, you will write data to the
drive. If you read from any location in N41, you will read data from
the drive.

"

"