5–17

Block Transfer Emulation Instructions

1203–5.5 September 1995

Message Operation

Fault Queue Entry Read Full reads the contents of the fault queue
specified in word 3 of the request. The response returns the fault text
which can be ASCII text. The text will have every two characters in
reverse order. In addition, the 1336 FORCE returns a time stamp,
indicating the day and time the fault occurred.

If an error has occurred, word 2 of the response returns a negative
value.

Example

In this example, Fault Queue Entry number 3 was retrieved from a
1336 PLUS drive. The drive response returned the ASCII text Drive
Reset Flt
, with each character reversed. The fault code for this
example is 22.

Data File Format

* Example only – These values vary depending on parameters and products.
# ASCII Display values

8308*

22*

r D

\00\12

\07\00

30313*

8293* 25938*

25971*

8308*

\03\00

v i

l F

e

t

\00\16

27718*

e R e s

t

3

1792

3*

18

1792

3*

29252*

0

N10:0

N10:90

1

2

3

4

5

6

7

8

9

PLC request

Drive response

N10:100

N10:90

#

N10:100

#